Home/Catalogue

Instrument catalogue

30 instruments across 9 families, made by instrument factories in Chuzhou and Tianchang. Prices are issued per order because range, material and connection change the model. Search by model or parameter, filter by family, then open the product page for the full table.

30 models
PG-100Pressure

Bourdon tube pressure gauge, Ø100

The general-purpose gauge most lines are still specified with: dry or liquid-filled case, 0–40 bar.

Range0–1 bar up to 0–40 bar
Accuracy±1.6 % FS
PG-150Pressure

Process pressure gauge, Ø150

Large dial, all-stainless wetted parts, ±1.0 % FS — for operators who read it from the walkway.

Range0–1.6 bar up to 0–100 bar
Accuracy±1.0 % FS
PT-20IPressure

Pressure transmitter, 4–20 mA

Piezoresistive transmitter with a 316L diaphragm; 0–16 bar, two-wire, HART on request.

Range0–100 mbar up to 0–60 bar, adjustable
Accuracy±0.5 % FS (0.25 % optional)
PD-10Pressure

Differential pressure transmitter

Two-port DP cell for filter monitoring and flow by orifice; 0–250 kPa, square-root output available.

Range0–2 kPa up to 0–2.5 MPa
Static pressureup to 16 MPa
PG-63NPressure

Utility gauge, Ø63, glycerine filled

The small liquid-filled gauge that survives a pump skid: 0–25 bar, ±2.5 % FS, brass internals.

Range0–1 bar up to 0–25 bar
Accuracy±2.5 % FS
PS-15Pressure

Adjustable pressure switch

Mechanical switch with a settable trip point and SPDT contact, 0.5–10 bar, for interlock and alarm duty.

Set range0.5–10 bar, adjustable
Dead band0.3–1.0 bar, fixed by spring
WRK-230Temperature

K-type thermocouple assembly

Ø6 mm 304 sheath, 0–1100 °C, fixed thread and 2 m lead — the assembly local factories make by the thousand.

TypeK (NiCr-NiSi), single or duplex
Range0–1100 °C, class I tolerance
WZP-230Temperature

PT100 resistance thermometer

Three-wire PT100 in a Ø6 316L sheath, −50 to 200 °C, for the accuracy a thermocouple cannot hold.

ElementPT100, class A or class B
Range−50 to +200 °C (400 °C on request)
WSS-411Temperature

Bimetallic thermometer, Ø100

No power, no wiring: a bimetal coil in a stainless stem, −20 to 150 °C, read straight off the dial.

Range−20 to +150 °C (up to 500 °C optional)
Accuracy±1.5 % FS
TT-30Temperature

Head-mount temperature transmitter

Fits inside a standard connection head: PT100 or thermocouple in, 4–20 mA out, HART optional.

InputPT100 / PT1000 / thermocouple J, K, T, E
Output4–20 mA, two-wire
EM-50Flow

Electromagnetic flowmeter, DN50

Full-bore magnetic meter, PTFE liner, 4–20 mA plus pulse, no straight-run penalty on slurries.

SizeDN15–DN300 (DN50 shown)
Range0.5–10 m/s, four ranges settable
VX-25Flow

Vortex flowmeter, DN25

Steam, gas or liquid in one body; no moving parts, 4–20 mA and totaliser, DN25 to DN300.

SizeDN15–DN300 (DN25 shown)
Mediumliquid, gas, saturated steam
LZ-25Flow

Rotameter, DN25

A glass tube and a float: the cheapest honest flow reading on a small line, 0.1–10 m³/h of water.

Range0.1–10 m³/h water (air ranges to order)
Accuracy±2.5 % FS
TU-40Flow

Turbine flowmeter, DN40

Tight tolerance on clean low-viscosity liquids: ±1.0 %, 4–20 mA and pulse out.

SizeDN15–DN100 (DN40 shown)
Range0.5–15 m³/h
MG-15Level

Magnetic level gauge

A magnetic float in a sealed tube moves red and white flags outside it — readable in daylight, at pressure.

Centres300–2000 mm, cut to the tank
Pressureup to 4.0 MPa
RD-60Level

Radar level transmitter, 26 GHz

Non-contact level to 15 m through dust, steam and foam; 4–20 mA, no moving parts in the tank.

Range0–15 m (0–30 m option)
Accuracy±5 mm
US-30Level

Ultrasonic level transmitter

0–8 m on water, slurry and chemicals, with a temperature-compensated echo; cheap and non-contact.

Range0–8 m (0–20 m option)
Accuracy±0.25 % FS
HY-20Level

Hydrostatic level transmitter

Submersible 316L diaphragm on a vented cable: level from pressure, 0–5 m H2O, 4–20 mA.

Range0–1 m up to 0–50 m H2O
Accuracy±0.5 % FS (0.25 % option)
XMT-1000Display & control

Digital panel meter

4-digit meter with universal input, relay alarms and a 24 V loop supply — the panel's front line.

InputTC, RTD, 4–20 mA, 0–10 V, resistance
Display4-digit LED, 0.56 inch
PID-700Display & control

PID temperature controller

Auto-tuning PID with relay or SSR output and a second alarm; the thermostat replacement that holds ±0.5 °C.

InputTC or RTD, universal
Outputrelay, SSR drive, 4–20 mA
DR-16Display & control

Paperless recorder, 16 channel

Sixteen inputs on one 7-inch screen, logged to SD card — the record a paper chart used to be.

Channels16 universal inputs
Display7 inch TFT touch
PH-10Analysis

pH / ORP transmitter

Glass electrode, 0–14 pH, 4–20 mA and two relays; the dosing loop in a wastewater plant.

Range0–14 pH / ±1000 mV ORP
Accuracy±0.02 pH
CD-20Analysis

Conductivity transmitter

Two-electrode cell from 0–2000 µS/cm, temperature-compensated, with a 4–20 mA output for the RO skid.

Range0–20 / 0–200 / 0–2000 µS/cm
Accuracy±1.0 % FS
KXC-KCables

Thermocouple compensation cable, KX

KX-type pair with overall shield, 2 × 0.5 mm², sold by the metre or cut to the run.

TypeKX (K-type compensation)
Conductors2 × 0.5 mm², stranded
CTRL-4×1.5Cables

Shielded control cable, 4 × 1.5 mm²

Four-core shielded control cable for 4–20 mA and 24 V circuits, cut to length, PVC or LSZH.

Cores4 × 1.5 mm², class 2 stranded
Shieldaluminium foil with tinned copper drain
TR-C100Cable tray

Channel cable tray, 100 mm

Perforated channel tray, 1.5–3.0 mm steel, hot-dip galvanised, with covers and bends cut to the drawing.

Width50 / 100 / 150 / 200 mm
Height25 / 40 / 50 mm
TR-L200Cable tray

Ladder cable tray, 200 mm

Ladder tray on 300 mm rungs for heavy cable runs and airflow; galvanised steel, straight and bends.

Width150–600 mm
Side height60 / 80 / 100 mm
JB-24Electrical & test

Instrument junction box, 304 SS

IP66 enclosure with 24 terminals, cable glands and a mounting plate; the box at the end of the cable run.

Enclosure304 SS, 300 × 200 × 120 mm
ProtectionIP66
DM-800Electrical & test

Digital multimeter, 600 V CAT III

True-RMS meter with a 4–20 mA range, continuity and a backlit display — bench to field.

DC voltage0–600 V, 0.5 % accuracy
AC voltage0–600 V true-RMS
IR-5KElectrical & test

Insulation resistance tester, 5 kV

250 V to 5 kV test voltages with PI and DAR — the cable test before energising.

Test voltage250 / 500 / 1000 / 2500 / 5000 V
Range0–10 TΩ

Documents: datasheet and calibration certificate are issued with each quotation on request.