Electromagnetic flowmeter, DN50
Full-bore magnetic meter, PTFE liner, 4–20 mA plus pulse, no straight-run penalty on slurries.
Line illustration. Photographs of the supplied unit and its nameplate are sent with the quotation.
Overview
A flanged electromagnetic meter with a PTFE liner and Hastelloy electrodes, sized DN15 to DN300. It reads conductive liquids with solids in suspension, which is where a turbine or a vortex meter stops working.
Specifications
| Size | DN15–DN300 (DN50 shown) |
|---|---|
| Range | 0.5–10 m/s, four ranges settable |
| Accuracy | ±0.5 % of reading |
| Liner / electrode | PTFE / Hastelloy C or 316L |
| Output | 4–20 mA, pulse, RS485 Modbus |
| Protection | IP65 converter, IP68 sensor option |
Typical values for this family. The datasheet issued with your quotation states the exact figures for the unit supplied.
Features
- Empty-pipe detection stops false totalising
- Bi-directional totaliser with two relays
- Converter separable up to 30 m from the sensor
Options
- Rubber or PFA liner for abrasive media
- Sanitary clamp body
- Battery-powered converter for remote sites
Typical applications
- Water supply and wastewater billing
- Slurries, pulp and chemical dosing
- CIP and product transfer in food plants
More in Flow
Same family, same quotation process. Open a product to compare parameters side by side.
Vortex flowmeter, DN25
Steam, gas or liquid in one body; no moving parts, 4–20 mA and totaliser, DN25 to DN300.
Rotameter, DN25
A glass tube and a float: the cheapest honest flow reading on a small line, 0.1–10 m³/h of water.
Turbine flowmeter, DN40
Tight tolerance on clean low-viscosity liquids: ±1.0 %, 4–20 mA and pulse out.