TU-40 · Flow

Turbine flowmeter, DN40

Tight tolerance on clean low-viscosity liquids: ±1.0 %, 4–20 mA and pulse out.

Line illustration. Photographs of the supplied unit and its nameplate are sent with the quotation.

Overview

A stainless turbine rotor with a magnetic pickup gives a pulse count proportional to volume. On diesel, solvents and DI water it is more accurate than a magnetic meter at a lower price.

Specifications

SizeDN15–DN100 (DN40 shown)
Range0.5–15 m³/h
Accuracy±1.0 % of reading
Body304 or 316L SS
Outputpulse, 4–20 mA, local totaliser
Pressureup to 6.3 MPa

Typical values for this family. The datasheet issued with your quotation states the exact figures for the unit supplied.

Features

  • Rotor and bearing replaceable in the field
  • Upstream straight run of 10 D keeps the accuracy
  • Local batch totaliser with reset

Options

  • Sanitary tri-clamp body
  • High-temperature pickup
  • Mechanical register for no-power totalising

Typical applications

  • Fuel and lube oil transfer
  • Solvent and DI water batching
  • Filling machines and dispensers