Turbine flowmeter, DN40
Tight tolerance on clean low-viscosity liquids: ±1.0 %, 4–20 mA and pulse out.
Line illustration. Photographs of the supplied unit and its nameplate are sent with the quotation.
Overview
A stainless turbine rotor with a magnetic pickup gives a pulse count proportional to volume. On diesel, solvents and DI water it is more accurate than a magnetic meter at a lower price.
Specifications
| Size | DN15–DN100 (DN40 shown) |
|---|---|
| Range | 0.5–15 m³/h |
| Accuracy | ±1.0 % of reading |
| Body | 304 or 316L SS |
| Output | pulse, 4–20 mA, local totaliser |
| Pressure | up to 6.3 MPa |
Typical values for this family. The datasheet issued with your quotation states the exact figures for the unit supplied.
Features
- Rotor and bearing replaceable in the field
- Upstream straight run of 10 D keeps the accuracy
- Local batch totaliser with reset
Options
- Sanitary tri-clamp body
- High-temperature pickup
- Mechanical register for no-power totalising
Typical applications
- Fuel and lube oil transfer
- Solvent and DI water batching
- Filling machines and dispensers
More in Flow
Same family, same quotation process. Open a product to compare parameters side by side.
Electromagnetic flowmeter, DN50
Full-bore magnetic meter, PTFE liner, 4–20 mA plus pulse, no straight-run penalty on slurries.
Vortex flowmeter, DN25
Steam, gas or liquid in one body; no moving parts, 4–20 mA and totaliser, DN25 to DN300.
Rotameter, DN25
A glass tube and a float: the cheapest honest flow reading on a small line, 0.1–10 m³/h of water.